7600 Series Specifications

The 7600 Series HMS is discontinued. Please consider the MagRS instead.

 7604 7607 7610 
Magnetic fieldPlease consult
Lake Shore for
10 in magnet option information
Room temp±1.3 T±2 T
Variable temp±0.87 T±1.2 T
Temperature
Standard77 K or room temperature
CCR15 K to 350 K
Oven350 K to 800 K
Carrier concentration density1 × 106 to 1 × 1019 cm-3
Mobility1 to 1 × 105 cm2/V s
Current (A)±10 nA to ±1 A
Voltage (V)0 V to 200 V
Resistance range (standard)2% accuracy—VdP minimum: 40 mΩ, HB minimum: 10 mΩ, maximum: 10 MΩ
System equipment
Sample holder module75011 room temperature/77 K; 2-sided sample cards 
Sample holder kit (included with sample holder module)(50) 671-209s, (10) 671-202s, (1) 671-205, (1) 671-260, (1) 671-250, and (10) 1-inch sheets of indium foil
Sample sizeUp to 10 × 14 mm (0.4 × 0.6 in)on a 25 × 75 mm (1 × 3 in) card; up to 60 mm (2.4 in) square on an 82 × 93 mm (3.2 × 3.7 in) cardUp to 76 mm (3 in) in diameter
Number of samplesUp to 4 (2 standard)
Model 475 gaussmeter1
Keithley equipment
2400 SourceMeter1
2700 Multimeter1
7709 6 × 8 Matrix Card1 (2 included with 4-sample configuration)
MagnetEM4-HVAEM7-HV
Pole diameter102 mm (4 in)178 mm (7 in)
Pole face diameter102 mm (4 in)152 mm (6 in)76.2 mm (3 in)
Max magnetic field at room temperature1.3 T (13 kG)at 25 mm (1 in)air gap1.6 T (16 kG)at 25 mm (1 in)air gap2.17 T (21.7 kG)at 25 mm (1 in)air gap
Max magnetic field at variable temperature0.87 T (8.7 kG)at 51 mm (2 in)air gap1.18 T (11.8 kG)at 51 mm (2 in)air gap1.47 T (14.7 kG)at 51 mm (2 in)air gap
Field homogeneity±0.1% over 10 mm3 (0.4 in3)±0.1% over centered 51 mm (2 in) diameter circle
Cooling water requirementsTap water or closed-cycle cooling system (optional chiller available)
Inlet temperature25 °C (77 °F) maximum32 °C (90 °F) maximum
Pressure drop200 kPa (30 psi)220 kPa (32 psi)
Flow rate7.6 L (2 gal)/min11.4 L (3 gal)/min
Water chiller cooling capacity2.5 kW (8,530 BTU)/h5 kW (17,060 BTU)/h
Bipolar magnet power supply643648
ModeDC
Maximum output±35 V ±70 A (2450 W)±70 V ±135 A (9.1 kW nominal)
AC line input204/208 VAC ±10%, 13 A/phase;220/230 VAC ±10%, 12 A/phase;380 VAC ±10%, 7 A/phase;400/415 VAC ±10%, 6.5 A/phase at 50/60 Hz200 VAC ±10%, 41 A/phase;
208 VAC ±10%, 40 A/phase;
220 VAC ±10%, 38 A/phase;
230 VAC ±10%, 37 A/phase;
380 VAC ±10%, 23 A/phase;
400 VAC ±10%, 21 A/phase;
415 VAC ±10%, 21 A/phase
Flow rate5.7 L (1.5 gal)/min minimum7.6 L (2 gal)/min
Cooling water requirementsTap water or closed cooling system (optional chiller available) +15 °C to +30 °CTap water or closed cooling system (optional chiller available) +15 °C to +30 °C
ComputerDell® computer with HDD, CD-ROM, 19-inch SVGA flat screen monitor, Windows® OS, Hall software, and National Instruments IEEE-488 USB adapter