| Quantity |
Part Number |
Description |
|
TTPX |
Up to 6 micro-manipulated stage 2-inch wafer probe station |
| Configurable Options: |
| Probes, probe tips, and cables are user configurable options and are required |
| Up to Six XYZ Precision Micro-manipulated Stages |
|
MMS-07 |
Micro-manipulated stage with thermal radiation shields, stainless steel welded bellows, and feedthrough ports—includes probe
arm and base; probes, probe tips, and cables sold separately |
| ZN50 DC/RF Probes |
|
ZN50-26U |
50 W stripline probe body mount |
| ZN50 Probe Tips (Alumina Ceramic Blade) (Click here for more information on Z50 probe tips) |
|
ZN50R-03-W |
3 μm radius, tungsten, up to 1 GHz* |
|
ZN50R-10-W |
10 μm radius, tungsten, up to 1 GHz* |
|
ZN50R-25-W |
25 μm radius, tungsten, up to 1 GHz* |
|
ZN50R-03-P7 |
3 μm radius, Paliney 7, up to 1 GHz* |
|
ZN50R-10-P7 |
10 μm radius, Paliney 7, up to 1 GHz* |
|
ZN50R-25-P7 |
25 μm radius, Paliney 7, up to 1 GHz* |
|
ZN50R-03-BECU |
3 μm radius, beryllium copper, up to 1 GHz* |
|
ZN50R-10-BECU |
10 μm radius, beryllium copper, up to 1 GHz* |
|
ZN50R-25-BECU |
25 μm radius, beryllium copper, up to 1 GHz* |
|
ZN50R-100-BECU |
100 μm radius, beryllium copper, up to 1 GHz* |
|
ZN50R-200-BECU |
200 μm radius, beryllium copper, up to 1 GHz* |
| * Maximum frequency is 50 MHz with ZN50C-G or ZN50C-T cable. Maximum frequency is 1 GHz with MWC-10-00K-NM cable. |
| ZN50 DC/RF Cables (Click here for more information on Z50 cables) |
|
ZN50C-G |
Ultra-miniature cryogenic coaxial probe cable with SMA plug at probe end, BNC feedthrough, and grounded shield (shielded
measurements to 50 MHz, max cable temp 350 K, max sample temp 675 K) |
|
ZN50C-T |
Ultra-miniature cryogenic coaxial probe cable with SMA plug at probe end to 3-lug triaxial feedthrough (for low leakage guarded measurements to 50 MHz, max cable temp 350 K, max sample temp 675 K) |
|
MWC-07-00K |
Semirigid microwave coaxial probe cable with K (SMA compatible) plug at probe end and K (SMA compatible) socket at
feedthrough end (for measurements to 1 GHz*, max cable temp 350 K, max sample temp 675 K) |
| *S21 > -10 dB up to 1 GHz, except for a (-40 dB) spike between 400 MHz and 800 MHz depending on probe model and placement;
S11 < -3 dB up to 1 GHz |
| GSG Microwave Probes (Click here for more information on GSG microwave probes) |
|
GSG-050-40A-26U-E |
K connector, 40 GHz, 50 μm pitch |
|
GSG-100-40A-26U-E |
K connector, 40 GHz, 100 μm pitch |
|
GSG-150-40A-26U-E |
K connector, 40 GHz, 150 μm pitch |
|
GSG-200-40A-26U-E |
K connector, 40 GHz, 200 μm pitch |
|
GSG-250-40A-26U-E |
K connector, 40 GHz, 250 μm pitch |
| |
|
GSG-050-50A-26U-E |
2.4 mm connector, 50 GHz, 50 μm pitch |
|
GSG-100-50A-26U-E |
2.4 mm connector, 50 GHz, 100 μm pitch |
|
GSG-150-50A-26U-E |
2.4 mm connector, 50 GHz, 150 μm pitch |
|
GSG-200-50A-26U-E |
2.4 mm connector, 50 GHz, 200 μm pitch |
|
GSG-250-50A-26U-E |
2.4 mm connector, 50 GHz, 250 μm pitch |
| |
|
GSG-050-67A-26U-E |
1.85 mm connector, 67 GHz, 50 μm pitch |
|
GSG-100-67A-26U-E |
1.85 mm connector, 67 GHz, 100 μm pitch |
|
GSG-150-67A-26U-E |
1.85 mm connector, 67 GHz, 150 μm pitch |
|
GSG-200-67A-26U-E |
1.85 mm connector, 67 GHz, 200 μm pitch |
|
GSG-250-67A-26U-E |
1.85 mm connector, 67 GHz, 250 μm pitch |
|
GSG-TPM |
Theta planarization module with upgraded manipulator to accommodate microwave probe rotation mechanism for in situ probe planarization (included with each GSG probe ordered with a probe station. When purchasing a GSG probe alone, GSG-TPM is not included) |
| GSG Microwave Cables (Click here for more information on GSG microwave cables) |
|
MWC-07-00K |
Semirigid microwave coaxial probe cable with K (SMA compatible) plug at probe end and K (SMA compatible) socket at
feedthrough end (for measurements to 40 GHz, max cable temp 350 K, max sample temp 675 K) |
|
MWC-07-240 |
Semirigid microwave coaxial probe cable with a 2.4 mm plug at probe and socket feedthrough ends (for measurements to 50
GHz, max cable temp 350 K, max sample temp 675 K) |
|
MWC-07-185 |
Semirigid microwave coaxial probe cable with a 1.85 mm plug at probe and socket feedthrough ends (for measurements to
67 GHz, max cable temp 350 K, max sample temp 675 K) |
| Sample holders – Each base system includes one SH-1.25-G (grounded) sample holder (Click here for more information on sample holders) |
|
SH-1.25-G |
Grounded sample holder for up to 32 mm (1.25 in) diameter samples (475 K) |
|
SH-1.25-I |
Isolated sample holder for up to 32 mm (1.25 in) diameter samples (400 K) |
|
SH-1.25-C |
Coaxial sample holder for up to 32 mm (1.25 in) diameter samples (400 K)* |
|
SH-1.25-T |
Triaxial sample holder for up to 32 mm (1.25 in) diameter samples (400 K)** |
|
SH-2.00-G |
Grounded sample holder for up to 51 mm (2 in) diameter samples (475 K) |
|
SH-2.00-C |
Coaxial sample holder for up to 51 mm (2 in) diameter samples (400 K)* |
|
SH-2.00-T |
Triaxial sample holder for up to 51 mm (2 in) diameter samples (400 K)** |
| Optical Access Sample Holders (each) — 5 mm (0.2 in) diameter optical access*** |
|
SH-1.25-G-O*** |
Optical access grounded sample holder for up to 32 mm (1.25 in) diameter samples (475 K) |
|
SH-1.25-I-O*** |
Optical access isolated sample holder for up to 32 mm (1.25 in) diameter samples (400 K) |
|
SH-1.25-C-O*** |
Optical access coaxial sample holder for up to 32 mm (1.25 in) diameter samples (400 K)* |
|
SH-1.25-T-O*** |
Optical access triaxial sample holder for up to 32 mm (1.25 in) diameter samples (400 K)** |
|
SH-2.00-G-O*** |
Optical access grounded sample holder for up to 51 mm (2 in) diameter samples (475 K) |
|
SH-2.00-C-O*** |
Optical access coaxial sample holder for up to 51 mm (2 in) diameter samples (400 K)* |
|
SH-2.00-T-O*** |
Optical access triaxial sample holder for up to 51 mm (2 in) diameter samples (400 K)** |
*Coaxial sample holders require one FT-BNC or FT-TRIAX feedthrough as listed below
**Triaxial sample holders require one FT-TRIAX feedthrough as listed below
***Optical access sample holders require one FT-OPTIC optical access kit as listed below |
|
FT-BNC |
Coaxial feedthrough and coaxial cable, installed and wired |
|
FT-TRIAX |
Triaxial feedthrough and coaxial cable, installed and wired |
|
FT-OPTIC |
Optical access kit—includes window, window holder, tower, and related components |
| Probe Station Options: |
|
PS-FOA |
Fiber optic probe arm modification. Transmit or receive light or IR/UV radiation. Fiber optic terminated with SMA connector or
compression feedthrough. (Fiber optic wire not included and priced separately based on requirements outlined in fiber optic worksheet.
Fiber optic and probe cannot be used simultaneously.) |
|
PS-Z16 |
16:1 zoom microscope upgrade; provides 4 μm resolution NOTE: consult Lake Shore for field upgrade |
|
PS-HTA |
High temperature sample stage for temperature operation from 20 K to 675 K. Integrated into the stage are a 51 mm (2 in) diameter coaxial sample holder, thermal standoff, calibrated PT-100 temperature sensor, heater, wiring, and cabling. The high temperature sample stage is interchangeable; standard sample holders can be used when the high temperature sample stage is removed. NOTE: reduces Z-axis travel to 12 mm; requires manual switching of 100 W radiation shield heater and sensor for closed loop control. Optional Model 336 temperature controller available for dedicated control loop. |
|
PS-LT |
3.2 K base temperature stage pumping option—includes system modifications, stainless steel flex hose for pump connection, and Varian DS402 rotary pump (12.3 CFM at 60 Hz with oil mist eliminator on output [with oil return], inlet oil demister); 50 Hz operation may increase base temperature |
|
PS-PLVI-25 |
Pump-line vibration isolator—includes NW 25 fittings, 1 m stainless steel bellows, clamps, and rings (placed between pump cart and system); requires one bag of cement. NOTE: for use with PS-LT |
|
PS-V81DPC |
Compact turbo pumping system—includes Varian V-81 turbo pump with oil free dry scroll backing pump, vacuum gauge for high vacuum, controller, and adaptors (specify 120 V/60 Hz or 220 V/50 Hz) |
|
PS-PLVI-40 |
Pump-line vibration isolator—includes NW 40 fittings, 1 m stainless steel bellows, clamps, and rings (placed between pump cart and system); requires one bag of cement. NOTE: for use with PS-V81DPC |
|
PS-DPC |
Automatic Dewar (gas) pressure controller, regulates Dewar liquid flow |
|
PS-LN2 |
Nitrogen Dewar with stainless fittings, gauges, and adaptors; allows LN2 use with the LHe transfer line |
|
PS-STAND-TTPX |
Heavy duty welded steel stand—provides stable platform for TTPX probe station |
|
PS-TTVIS |
Pneumatic tabletop vibration isolation system—compact pneumatic isolator with self-leveling (isolator resonance: vertical 3.2 Hz,
horizontal 3.6 Hz; isolation efficiency at 10 Hz: vertical 90%, horizontal 96%; amplification at resonance: vertical 12 dB, horizontal 10 dB);
requires 40 psi nitrogen or air |
|
PS-OAC |
Oil-less air compressor for PS-TMC (only available in 120 V) |
|
PA-SEN |
Probe arm modification with temperature sensor installed and wired to a 6-pin feedthrough |
|
PS-PAB-07 |
Probe arm and base |
|
CS-5 |
Calibration substrate for GSG probes—pad size: 50 μm2; calibration type: SOLT (short-open-load-through), LRL (line-reflective-line),
LRM (line-reflective-match); pitch range: 75 to 250 μm |
|
CS-15 |
Calibration substrate for GSG probes—pad size: 25 μm2; calibration type: SOLT (short-open-load-through), LRL (line-reflective-line),
LRM (line-reflective-match); pitch range: 40 to 150 μm |
| |
|
| |
| U.S.
And Canada Only Shipping |
| At this time, we cannot ship or bill web orders outside of the United States and Canada. We cannot accept credit cards issued from a bank outside of the U.S. or Canada. If you are outside of the U.S. or Canada and would like export prices or order information, please contact your local sales representative by visiting http://www.lakeshore.com/com/sr.html. |
|
| Sales
Tax: Lake Shore currently collects sales tax in the following
states: AZ, CA, FL, IN, OH, SC WA |
|
|
Terms & Conditions | Warranty Statement | Shipping Charges |
| Please submit your customized system for quotation by clicking on the button below. You will then be prompted to check your specifications, and once approved, these will be e-mailed to our sales department for a quote. |
| |
| |
|
|
|
 |
 |
 |