Contact: info@lakeshore.com Lakeshore.com Search www.lakeshore.com Contact Us Ordering / Pricing Products Home
Desert Web Logo
View Cart
 
Home > Lake Shore Products > Cryogenic Probe Stations > Model TTP4 Cryogenic Probe Station Request A Quote
 

 Model TTP4 Cryogenic Probe Station

 
Model TTP4 Cryogenic Probe Station Product Overview Technical Specifications for Model TTP4 Cryogenic Probe Station Downloads for Model TTP4 Cryogenic Probe Station
 
Quantity Part Number Description 
TTP4 4 ultra-stable micro-manipulated probe stages, Ø38 mm (1.25 in) sample, 4.2 K to 475 K
Installation/Training:
PS-INSTALL 2 days on-site installation/training
Configurable Options:
Probes, probe tips, and cables are user configurable options and are required
ZN50 Probe Body (50 ohm Stripline probes)
ZN50-26U Stripline probe body mount
ZN50 Probe tips (alumina ceramic blade) one required with each ZN50 probe body (Click here for more information on ZN50 Probes)
ZN50R-03-W 3 µm radius, tungsten, up to 1 GHz1
ZN50R-10-W 10 µm radius, tungsten, up to 1 GHz1
ZN50R-25-W 25 µm radius, tungsten, up to 1 GHz1
 
ZN50R-03-P7 3 µm radius, Paliney 7, up to 1 GHz1
ZN50R-10-P7 10 µm radius, Paliney 7, up to 1 GHz1
ZN50R-25-P7 25 µm radius, Paliney 7, up to 1 GHz1
 
ZN50R-03-BeCu 3 µm radius, beryllium copper, up to 1 GHz1
ZN50R-10-BeCu 10 µm radius, beryllium copper, up to 1 GHz1
ZN50R-25-BeCu 25 µm radius, beryllium copper, up to 1 GHz1
ZN50R-100-BeCu 100 µm radius, beryllium copper, up to 1 GHz1
ZN50R-200-BeCu 200 µm radius, beryllium copper, up to 1 GHz1
1 Maximum frequency is 50 MHz with Z50-Cu-SS-3650G or Z50-Cu-SS-3650T cable. Maximum frequency is 1 GHz with K-085-K cable.
S21 > -10 dB up to 1 Ghz, except for a (-40 dB) spike between 400 MHz and 800 MHz depending on probe model and placement; S11 < -3 dB up to 1 GHz
 
Z50 Cables (one required per ZN50 probe body) (Click here for more information on Z50 Cables)
Z50-CU-SS-3650-G Ultra miniature cryogenic coaxial probe cable with SMA plug at probe end, BNC feedthrough, and grounded shield (shielded measurements to 50 MHz, 475 K)
Z50-CU-SS-3650-T Ultra miniature cryogenic coaxial probe cable with SMA connector at probe end to 2-lug triax feedthrough (for low leakage guarded measurements to 50 MHz, 475 K)
K-085-K-07 Stainless semi-rigid microwave coaxial probe cable with SMA plug at probe end and SMA jack at feedthrough end (for measurements to 1 GHz, 400 K)
GSG Microwave Probes (coplanar waveguide probes) (Click here for more information on GSG Microwave Probes)
GSG-050-40A-26U-D K connector, 50 µm pitch, 40 GHz
GSG-100-40A-26U-D K connector, 100 µm pitch, 40 GHz
GSG-150-40A-26U-D K connector, 150 µm pitch, 40 GHz
GSG-200-40A-26U-D K connector, 200 µm pitch, 40 GHz
GSG-250-40A-26U-D K connector, 250 µm pitch, 40 GHz
   
GSG-050-50A-26U-D 2.4 mm connector, 50 µm pitch, 50 GHz
GSG-100-50A-26U-D 2.4 mm connector, 100 µm pitch, 50 GHz
GSG-150-50A-26U-D 2.4 mm connector, 150 µm pitch, 50 GHz
GSG-200-50A-26U-D 2.4 mm connector, 200 µm pitch, 50 GHz
GSG-250-50A-26U-D 2.4 mm connector, 250 µm pitch, 50 GHz
   
GSG-050-67A-26U-D 1.8 mm connector, 50 µm pitch, 67 GHz
GSG-100-67A-26U-D 1.8 mm connector, 100 µm pitch, 67 GHz
GSG-150-67A-26U-D 1.8 mm connector, 150 µm pitch, 67 GHz
GSG-200-67A-26U-D 1.8 mm connector, 200 µm pitch, 67 GHz
GSG-250-67A-26U-D 1.8 mm connector, 250 µm pitch, 67 GHz
GSG-TPM Theta planarization module with upgraded manipulator to accommodate microwave probe rotation mechanism for in situ probe planarization (included with each GSG probe ordered with a probe station. When purchasing a GSG probe alone, GSG-TPM is not included)
GSG Microwave Cables (one required per microwave probe) (Click here for more information on GSG Microwave Cables)
K-085-K-07 Stainless semi-rigid microwave coaxial probe cable with K (SMA) plug at probe end and K (SMA) jack at feedthrough end (for measurements to 40 GHz, 400 K)
2.4-085-2.4-07 Stainless semi-rigid microwave coaxial probe cable with a 2.4 mm connector at probe and feedthrough ends (for measurements to 50 GHz, 400 K)
1.8-085-1.85-07 Stainless semi-rigid microwave coaxial probe cable with a 1.8 mm connector at probe and feedthrough ends (for measurements to 67 GHz, 400 K)
Sample Chucks (Holders) – one SH-1.25-G is included with the TTP4 (Click here for more information on Sample Chucks)
SH-1.25-G Grounded sample holder for up to Ø31.8 mm (1.25 in) diameter samples (475 K)
SH-1.25-I Isolated sample holder for up to Ø31.8 mm (1.25 in) diameter samples (400 K)
SH-1.25-C Coaxial sample holder for up to Ø31.8 mm (1.25 in) diameter samples (400 K)*
SH-1.25-T Triaxial sample holder for up to Ø31.8 mm (1.25 in) diameter samples (400 K)**
 
SH-2.00-G Grounded sample holder for up to Ø51 mm (2 in) diameter samples (475 K)
SH-2.00-C Coaxial sample holder for up to Ø51 mm (2 in) diameter samples (400 K)*
SH-2.00-T Triaxial sample holder for up to Ø51 mm (2 in) diameter samples (400 K)**
*Requires one FT-BNC or FT-TRIAX feedthrough as listed below – FT-Triax recommended
**Triaxial sample holders require an FT-TRIAX feedthrough as listed below
FT-BNC Coaxial feedthrough and coaxial cable, installed and wired
FT-TRIAX Triaxial feedthrough and coaxial cable, installed and wired
Probe Station Options:
PS-FOA Fiber optic probe arm modification. Transmit or receive light or IR/UV radiation. Fiber optic terminated with SMA connector or compression feedthrough. (Fiber optic wire not included. Fiber optic and probe cannot be used
simultaneously.)
PS-Z12.5 12.5:1 zoom monoscope upgrade for 4 µm resolution NOTE: upgrade is not field-installable
PS-Z16 16:1 zoom monoscope upgrade for 3 µm resolution NOTE: upgrade is not field-installable
PS-TC Supplemental temperature control providing two additional temperature sensor control channels and two power outputs—includes one Model 332 temperature controller, one external 100 W power supply, cable and accessories
PS-3K 3.2 K base temperature stage pumping option – includes system modifications, stainless steel flex hose for pump connection to Edwards E1M18 rotary pump (14.7 CFM at 60 Hz, with oil mist eliminator on output [with oil return], and inlet oil demister)
PS-DPC Automatic Dewar (gas) pressure controller, regulates Dewar liquid flow
PS-V81DP Turbo pumping system—includes Varian V-81 Turbo Pump cart with oil free dry scroll backing pump, vacuum gauging for high vacuum and fore line, controller, and adaptors (specify 110 V/60 Hz or 220 V/50 Hz)
PS-LN2 Nitrogen Dewar (with stainless fittings, gauges, and adapters) allowing LN2 use with helium transfer line
PS-PLVI-25 Pump-line vibration isolator—includes NW-25 fittings, 1 m stainless steel bellows, clamps, and rings (placed
between pump cart and system); requires one bag of cement
PS-LVS Low vibration, heavy PVC constructed non-magnetic stand with sand weighted legs and brass fittings NOTE: this option minimizes system vibration displacement at all frequencies
PS-TTVIS Pneumatic tabletop vibration isolation system—compact pneumatic isolator with self-leveling (isolator resonance: vertical 3.2 Hz, horizontal 3.6 Hz; isolation efficiency at 10 Hz: vertical 90%, horizontal 96%; amplification at
resonance: vertical 12 dB, horizontal 10 dB); requires PS-LVS (ordered separately) and 80 psi nitrogen or air
PS-TMC-A Stand with pneumatic vibration isolation system—gimbal piston isolator, actuators, supports, and granite slab
(supplied for weight)(isolator natural frequency: vertical 0.8 Hz, horizontal 1.0 Hz; isolation efficiency at 5 Hz:
vertical 80 to 97%, horizontal 60 to 90%; isolation efficiency at 10 Hz: vertical 90 to 99%, horizontal 70 to 95%); requires 80 psi nitrogen or air
PS-OAC Oil-less air compressor for PS-TTVIS or PS-TMC-A (only available in 110 V)
PA-SEN Probe arm modifcation with platinum temperature sensor installed and wired to a 6-pin feedthrough
PS-TTP4 Probe arm and base for TTP4 probe station
MMS-TTP4 Micro-manipulated stage for TTP4 probe station
CS-5 Calibration substrate for GSG probes. Pad size: 50 µ2; Calibration type: SOLT (short-open-load-through), LRL (line-reflective-line) LRM (line-reflective-match); Pitch range: 75 to 250 µ
CS-15 Calibration substrate for GSG probes. Pad size: 25 μm2; calibration type: SOLT (short-open-load-through),
LRL (line-reflective-line), LRM (line-reflective-match); pitch range: 40 to 150 μm
 
Special Request:
   
 
U.S. And Canada Only Shipping
At this time, we cannot ship or bill web orders outside of the United States and Canada. We cannot accept credit cards issued from a bank outside of the U.S. or Canada. If you are outside of the U.S. or Canada and would like export prices or order information, please contact your local sales representative by visiting http://www.lakeshore.com/com/sr.html.
Sales Tax: Lake Shore currently collects sales tax in the following states: AZ, CA, FL, IN, OH, SC WA