| Open cycle sample stage refrigerator |
4.5 K to 475 K |
| Cold head stage temperature sensor |
|
| Cold head stage heater |
100 W (2 parallel heaters, 50 W each) |
| |
| Cooled radiation shield and cooled IR-absorbing window above the sample |
| Temperature sensor |
Lake Shore Model DT-670C-CU silicon diode |
| Radiation shield heater |
100 W |
| Removable top lid with viewport |
Ø152 mm (6 in) window |
| |
| Temprature controller |
Lake Shore Model 340 with 3462 expansion card and one Model 142 200 W (2-channels, 100 W each) power supply (independent regulation of cold head stage, radiation shield, and probe arm temperature monitoring) |
| |
Vacuum chamber
Diameter |
25.4 cm (10 in) |
| Removable top lid with clear fused quartz viewport |
Ø91 mm (3.6 in) window |
| Probe ports |
6 surround the sample thermal radiation shield; each port is shielded by a super-insulating curtain to minimize direct 300 K blackbody radiation |
| |
| Machined aluminum base plate |
84.6 cm2 (33.3 in2) |
| |
| PS-TMC vibration isolation system |
Includes pneumatically driven gimbal piston isolator, actuators, and supports; self leveling with a resonant frequency below 2 Hz; requires 80 psi nitrogen or air |
| Isolator natural frequency |
Vertical 0.8 Hz, horizontal 1.0 Hz |
| Isolator efficiency at 5 Hz |
Vertical 80 to 97%, horizontal 60 to 90% |
| Isolator efficiency at 10 Hz |
Vertical 90 to 99%, horizontal 70 to 95% |
| |
| Six XYZ precision micro-manipulated probing stages |
| |
| Probe arms, thermal radiation shields, stainless steel welded bellows, and feedthrough ports |
| |
| Thermally linked probe mounts |
Probe mounts and radiation shield are thermally anchored to the cold head; one probe mount includes a platinum temperature sensor installed and wired to a 6-pin feedthrough |
| |
| Grounded sample holder |
SH-4.00-4G, accomodates up to a Ø10.2 cm (4 in) sample with a Ø50.8 mm (2 in) probe area |
| |
Optics
Zoom 70 monoscope |
7:1 zoom with 5 µm resolution |
| Color CCD camera |
|
| Swing arm |
Optics can be manipulated to view any part of the sample or wafer, and can be retracted and swung away to allow access to the top of the vacuum chamber for sample exchange |
| Video monitor |
High resolution, 17-inch |
| Sample illumination |
Coaxial via fiber optic or ring light from an adjustable light source and
power supply (must specify sample illumination at time of order) NOTE: Coaxial illumination is recommended for highly reflective materials |
| |
| High efficiency helium transfer line with foot valve for precise flow regulation |
| |
| Basic tools, spares, and cleaning kit |
 |
 |