| Quantity |
Part Number |
Description |
|
EMTTP4 |
5.5 kOe (0.55T) horizontal electromagnet field, 4 ultra-stable micro-manipulated probe stages, Ø 25 mm (1 in.) sample, 10 K to 450 K |
| Installation/Training: |
|
PS-INSTALL |
2 days on-site installation/training |
| Configurable Options: |
| Probes, probe tips, and cables are user configurable options and are required |
| ZI50 Stripline Probe Body Mount and Tips (Alumina Ceramic Blade) |
|
ZI50-03-W |
Probe body with 3 µm radius tungsten tip, up to 1 GHz1 |
|
ZI50-10-W |
Probe body with 10 µm radius tungsten tip, up to 1 GHz1 |
|
ZI50-25-W |
Probe body with 25 µm radius tungsten tip, up to 1 GHz1 |
|
ZI50-03-P7 |
Probe body with 3 µm radius Paliney 7 tip, up to 1 GHz1 |
|
ZI50-10-P7 |
Probe body with 10 µm radius Paliney 7 tip, up to 1 GHz1 |
|
ZI50-25-P7 |
Probe body with 25 µm radius Paliney 7 tip, up to 1 GHz1 |
|
ZI50-03-BeCu |
Probe body with 3 µm radius beryllium copper tip, up to 1 GHz1 |
|
ZI50-10-BeCu |
Probe body with 10 µm radius beryllium copper tip, up to 1 GHz1 |
|
ZI50-25-BeCu |
Probe body with 25 µm radius beryllium copper tip, up to 1 GHz1 |
|
ZI50-100-BeCu |
Probe body with 100 µm radius beryllium copper tip, up to 1 GHz1 |
|
ZI50-200-BeCu |
Probe body with 200 µm radius beryllium copper tip, up to 1 GHz1 |
| 1 Maximum frequency is 50 MHz with Z50-Cu-SS-3650G or Z50-Cu-SS-3650T cable. Maximum frequency is 1 GHz with K-085-K cable.
S21 > -10 dB up to 1 Ghz, except for a (-40 dB) spike between 400 MHz and 800 MHz depending on probe model and placement; S11 < -3 dB up to 1 GHz |
| Z50 Cables (one required per ZN50 probe) (Click here for more information on Z50 Cables) |
|
Z50-CU-SS-3650-G-12 |
Ultra miniature cryogenic coaxial probe cable with SMA plug at probe end, BNC feedthrough, and grounded shield (shielded measurements to 50 MHz, 450 K) |
|
Z50-CU-SS-3650-T-12 |
Ultra miniature cryogenic coaxial probe cable with SMA connector at probe end to 2-lug triax feedthrough (for low leakage guarded measurements to 50 MHz, 450 K) |
|
K-085-K-12 |
Stainless semi-rigid microwave coaxial probe cable with SMA plug at probe end and SMA jack at feedthrough end (for measurements to 1 GHz, 400 K) |
| GSG Microwave Probes (coplanar waveguide probes) (Click here for more information on GSG Microwave Probes) |
|
GSG-050-40A-DNM |
K connector, 50 µm pitch, 40 GHz |
|
GSG-100-40A-DNM |
K connector, 100 µm pitch, 40 GHz |
|
GSG-150-40A-DNM |
K connector, 150 µm pitch, 40 GHz |
|
GSG-200-40A-DNM |
K connector, 200 µm pitch, 40 GHz |
|
GSG-250-40A-DNM |
K connector, 250 µm pitch, 40 GHz |
| |
|
GSG-050-50A-DNM |
2.4 mm connector, 50 µm pitch, 50 GHz |
|
GSG-100-50A-DNM |
2.4 mm connector, 100 µm pitch, 50 GHz |
|
GSG-150-50A-DNM |
2.4 mm connector, 150 µm pitch, 50 GHz |
|
GSG-200-50A-DNM |
2.4 mm connector, 200 µm pitch, 50 GHz |
|
GSG-250-50A-DNM |
2.4 mm connector, 250 µm pitch, 50 GHz |
| |
|
GSG-050-67A-DNM |
1.8 mm connector, 50 µm pitch, 67 GHz |
|
GSG-100-67A-DNM |
1.8 mm connector, 100 µm pitch, 67 GHz |
|
GSG-150-67A-DNM |
1.8 mm connector, 150 µm pitch, 67 GHz |
|
GSG-200-67A-DNM |
1.8 mm connector, 200 µm pitch, 67 GHz |
|
GSG-250-67A-DNM |
1.8 mm connector, 250 µm pitch, 67 GHz |
|
GSG-TPM |
Theta planarization module with upgraded manipulator to accommodate microwave probe rotation mechanism for in situ probe planarization (included with each GSG probe ordered with a probe station. When purchasing a GSG probe alone, GSG-TPM is not included) |
| GSG Microwave Cables (one required per microwave probe) (Click here for more information on GSG Microwave Cables) |
|
K-085-K-12 |
Stainless semi-rigid microwave coaxial probe cable with K (SMMA) plug at probe end and K (SMA) jack at feedthrough end (for measurements to 40 GHz, 400 K) |
|
2.4-085-2.4-12 |
Stainless semi-rigid microwave coaxial probe cable with a 2.4 mm connector at probe and feedthrough ends (for measurements to 50 GHz, 400 K) |
|
1.8-085-1.85-12 |
Stainless semi-rigid microwave coaxial probe cable with a 1.8 mm connector at probe and feedthrough ends (for measurements to 67 GHz, 400 K) |
| Sample Chucks (Holders) – one SH-1.00-G is included with the EMTTP4 (Click here for more information on Sample Chucks) |
|
SH-1.00-G |
Grounded sample holder for up to Ø25 mm (1 in) samples (400 K) |
|
SH-1.00-I |
Isolated sample holder for up to Ø25 mm (1 in) samples (400 K) |
|
SH-1.00-C |
Coaxial sample holder for up to Ø25 mm (1 in) samples (400 K)* |
|
SH-1.00-T |
Triaxial sample holder for up to Ø25 mm (1 in) samples (400 K)** |
*Requires one FT-BNC or FT-TRIAX feedthrough as listed below – FT-Triax recommended
**Triaxial sample holders require an FT-TRIAX feedthrough as listed below |
|
FT-BNC |
Coaxial feedthrough and coaxial cable, installed and wired |
|
FT-TRIAX |
Triaxial feedthrough and coaxial cable, installed and wired |
| Probe Station Options: |
|
PS-FOA |
Fiber optic probe arm modification. Transmit or receive light or IR/UV radiation. Fiber optic terminated with SMA
connector or compression feedthrough. (Fiber optic wire not included. Fiber optic and probe cannot be used
simultaneously.) |
|
PS-Z12.5 |
12.5:1 zoom monoscope upgrade for 4 µm resolution NOTE: upgrade is not field-installable |
|
PS-Z16 |
16:1 zoom monoscope upgrade for 3 µm resolution NOTE: upgrade is not field-installable |
|
PS-EMTTP4-360 |
360° sample stage rotation NOTE: limits overall temperature range to 10 K to 400 K; ∆T between the sample and the
cold head stage temperature sensor is <±2 K over the full temperature range; recommended when taking
measurements using microwave probes. |
|
PS-DPC |
Automatic Dewar (gas) pressure controller, regulates Dewar liquid flow |
|
PS-V81DP |
Turbo pumping system—includes Varian V-81 Turbo Pump cart with oil free dry scroll backing pump, vacuum gauging for high vacuum and fore line, controller, and adaptors (specify 110 V/60 Hz or 220 V/50 Hz) |
|
PS-LN2 |
Nitrogen Dewar (with stainless fittings, gauges, and adapters) allowing LN2 use with helium transfer line |
|
PS-OAC |
Oil-less air compressor for PS-TTVIS or PS-TMC (only available in 110 V) |
|
PS-PLVI-40 |
Pump-line vibration isolator—includes NW-40 fittings, 1 m stainless steel bellows, clamps, and rings (placed
between pump cart and system); requires one bag of cement |
|
PA-SEN |
Probe arm modifcation with platinum temperature sensor installed and wired to a 6-pin feedthrough |
|
PA-EMTTP4 |
Probe arm and base for EMTTP4 probe station |
|
MMS-EMTTP4 |
Micro-manipulated stage for EMTTP4 probe station |
|
CS-5 |
Calibration substrate for GSG probes. Pad size: 50 µm2; calibration type: SOLT (short-open-load-through), LRL (line-reflective-line), LRM (line-reflective-match); pitch range: 75 to 250 µm |
|
CS-15 |
Calibration substrate for GSG probes. Pad size: 25 μm2; calibration type: SOLT (short-open-load-through),
LRL (line-reflective-line), LRM (line-reflective-match); pitch range: 40 to 150 μm |
|
RC-EM7-200230-60-CE |
Recirculating chiller; CP-55, 200 to 230 V, 60 Hz, 20 A, 5.05 kW, 6 gpm, 40 psi |
|
RC-EM7-400-50-CE |
Recirculating chiller; PD-2, 380 to 400 V, 50 Hz, 3 ph, 7 A, 4.54 kW, 3.2 gpm, 30 psi |
|
RC-EM7-200-50-CE |
Recirculating chiller; PD-2, 200 V, 50 Hz, 20 A, 4.54 kW, 3.2 gpm, 30 psi |
| |
|
| |
| U.S.
And Canada Only Shipping |
| At this time, we cannot ship or bill web orders outside of the United States and Canada. We cannot accept credit cards issued from a bank outside of the U.S. or Canada. If you are outside of the U.S. or Canada and would like export prices or order information, please contact your local sales representative by visiting http://www.lakeshore.com/com/sr.html. |
|
| Sales
Tax: Lake Shore currently collects sales tax in the following
states: AZ, CA, FL, IN, OH, SC WA |
|
|
Terms & Conditions | Warranty Statement | Shipping Charges |
| Please submit your customized system for quotation by clicking on the button below. You will then be prompted to check your specifications, and once approved, these will be e-mailed to our sales department for a quote. |
| |
| |
|
|
|
 |
 |
 |