| Quantity |
Part Number |
Description |
|
EMPX-HF |
Up to 4 micro-manipulated stage electromagnet horizontal field 1-inch wafer
probe station |
| Configurable Options: |
| Probes, probe tips, and cables are user configurable options and are required |
| Up to Four XYZ Precision Micro-manipulated Stages |
|
MMS-10 |
Micro-manipulated stage with thermal radiation shields, stainless steel welded bellows, and feedthrough ports—includes probe
arm and base; probes, probe tips, and cables sold separately |
| ZN50 DC/RF Probes |
|
ZN50 |
50 W stripline probe body mount |
| ZN50 Probe Tips (Alumina Ceramic Blade) |
|
ZN50R-03-W |
3 μm radius, tungsten, up to 1 GHz* |
|
ZN50R-10-W |
10 μm radius, tungsten, up to 1 GHz* |
|
ZN50R-25-W |
25 μm radius, tungsten, up to 1 GHz* |
|
ZN50R-03-P7 |
3 μm radius, Paliney 7, up to 1 GHz* |
|
ZN50R-10-P7 |
10 μm radius, Paliney 7, up to 1 GHz* |
|
ZN50R-25-P7 |
25 μm radius, Paliney 7, up to 1 GHz* |
|
ZN50R-03-BECU |
3 μm radius, beryllium copper, up to 1 GHz* |
|
ZN50R-10-BECU |
10 μm radius, beryllium copper, up to 1 GHz* |
|
ZN50R-25-BECU |
25 μm radius, beryllium copper, up to 1 GHz* |
|
ZN50R-100-BECU |
100 μm radius, beryllium copper, up to 1 GHz* |
|
ZN50R-200-BECU |
200 μm radius, beryllium copper, up to 1 GHz* |
| * Maximum frequency is 50 MHz with ZN50C-G or ZN50C-T cable. Maximum frequency is 1 GHz with MWC-10-00K-NM cable. |
| ZN50 DC/RF Cables (Click here for more information on Z50 cables) |
|
ZN50C-G |
Ultra-miniature cryogenic coaxial probe cable with SMA plug at probe end, BNC feedthrough, and grounded shield (shielded
measurements to 50 MHz, 400 K) |
|
ZN50C-T |
Ultra-miniature cryogenic coaxial probe cable with SMA plug at probe end to 3-lug triaxial feedthrough (for low leakage guarded measurements to 50 MHz, 475 K) |
|
MWC-10-00K-NM |
Non-magnetic semirigid microwave coaxial probe cable with K (SMA compatible) plug at probe end and K (SMA compatible) socket at feedthrough end (for high frequency measurements to 1 GHz*, 350 K) |
| *S21 > -10 dB up to 1 GHz, except for a (-40 dB) spike between 400 MHz and 800 MHz depending on probe model and placement;
S11 < -3 dB up to 1 GHz |
| GSG Microwave Probes (Click here for more information on GSG microwave probes) |
|
GSG-050-40A-E-NM |
K connector, 40 GHz, 50 μm pitch |
|
GSG-100-40A-E-NM |
K connector, 40 GHz, 100 μm pitch |
|
GSG-150-40A-E-NM |
K connector, 40 GHz, 150 μm pitch |
|
GSG-200-40A-E-NM |
K connector, 40 GHz, 200 μm pitch |
|
GSG-250-40A-E-NM |
K connector, 40 GHz, 250 μm pitch |
| |
|
GSG-050-50A-E-NM |
2.4 mm connector, 50 GHz, 50 μm pitch |
|
GSG-100-50A-E-NM |
2.4 mm connector, 50 GHz, 100 μm pitch |
|
GSG-150-50A-E-NM |
2.4 mm connector, 50 GHz, 150 μm pitch |
|
GSG-200-50A-E-NM |
2.4 mm connector, 50 GHz, 200 μm pitch |
|
GSG-250-50A-E-NM |
2.4 mm connector, 50 GHz, 250 μm pitch |
| |
|
GSG-050-67A-E-NM |
1.85 mm connector, 67 GHz, 50 μm pitch |
|
GSG-100-67A-E-NM |
1.85 mm connector, 67 GHz, 100 μm pitch |
|
GSG-150-67A-E-NM |
1.85 mm connector, 67 GHz, 150 μm pitch |
|
GSG-200-67A-E-NM |
1.85 mm connector, 67 GHz, 200 μm pitch |
|
GSG-250-67A-E-NM |
1.85 mm connector, 67 GHz, 250 μm pitch |
|
GSG-TPM |
Planarization module with upgraded manipulator to accommodate microwave probe rotation mechanism for in situ probe planarization (included with each GSG probe ordered with a probe station. When purchasing a GSG probe alone, GSG-TPM is not included) |
| GSG Microwave Cables (Click here for more information on GSG microwave cables) |
|
MWC-10-00K-NM |
Non-magnetic semirigid microwave coaxial probe cable with K (SMA compatible) plug at probe end and K (SMA compatible) socket at feedthrough end (for measurements to 40 GHz, 350 K) |
|
MWC-10-240-NM |
Non-magnetic semirigid microwave coaxial probe cable with a 2.4 mm plug at probe and socket feedthrough ends
(for measurements to 50 GHz, 350 K) |
|
MWC-10-185-NM |
Non-magnetic semirigid microwave coaxial probe cable with a 1.85 mm plug at probe and socket feedthrough ends
(for measurements to 67 GHz, 350 K) |
| Sample holders – Each base system includes one SH-1.00-G-EM (grounded) sample holder (Click here for more information on sample holders) |
|
SH-1.00-G-EM |
Grounded sample holder for up to 25 mm (1 in) diameter samples (400 K) |
|
SH-1.00-I-EM |
Isolated sample holder for up to 25 mm (1 in) diameter samples (400 K) |
|
SH-1.00-C-EM |
Coaxial sample holder for up to 25 mm (1 in) diameter samples (400 K)* |
|
SH-1.00-T-EM |
Triaxial sample holder for up to 25 mm (1 in) diameter samples (400 K)** |
*Coaxial sample holders require one FT-BNC or FT-TRIAX feedthrough as listed below
**Triaxial sample holders require one FT-TRIAX feedthrough as listed below |
|
FT-BNC |
Coaxial feedthrough and coaxial cable, installed and wired |
|
FT-TRIAX |
Triaxial feedthrough and coaxial cable, installed and wired |
| Probe Station Options: |
|
PS-FOA |
Fiber optic probe arm modification. Transmit or receive light or IR/UV radiation. Fiber optic terminated with SMA connector or
compression feedthrough. (Fiber optic wire not included and priced separately based on requirements outlined in fiber optic worksheet.
Fiber optic and probe cannot be used simultaneously.) |
|
PS-Z16 |
16:1 zoom microscope upgrade; provides 5 μm resolution NOTE: consult Lake Shore for field upgrade |
|
PS-360-EMPX |
360° sample stage rotation NOTE: limits overall temperature range to 10 K to 400 K; ΔT between the sample and the
sample stage temperature sensor is <±2 K over the full temperature range; recommended when taking measurements using
microwave probes; consult Lake Shore for information on upgrading existing probe station |
|
PS-DPC |
Automatic Dewar (gas) pressure controller, regulates Dewar liquid flow |
|
PS-V81DP |
Turbo pumping system—includes Varian V-81 turbo pump cart with oil free dry scroll backing pump, vacuum gauging for high
vacuum and fore line, controller, and adaptors (specify 120 V/60 Hz or 220 V/50 Hz) |
|
PS-PLVI-40 |
Pump-line vibration isolator—includes NW 40 fittings, 1 m stainless steel bellows, clamps, and rings (placed between pump cart
and system); requires one bag of cement |
|
PS-LN2 |
Nitrogen Dewar with stainless fittings, gauges, and adaptors; allows LN2 use with the LHe transfer line |
|
PS-OAC |
Oil-less air compressor for PS-TMC (only available in 120 V) |
|
PA-SEN |
Probe arm modification with temperature sensor installed and wired to a 6-pin feedthrough |
|
PS-PAB-10 |
Probe arm and base |
|
CS-5 |
Calibration substrate for GSG probes—pad size: 50 μm2; calibration type: SOLT (short-open-load-through), LRL (line-reflective-line),
LRM (line-reflective-match); pitch range: 75 to 250 μm |
|
CS-15 |
Calibration substrate for GSG probes—pad size: 25 μm2; calibration type: SOLT (short-open-load-through), LRL (line-reflective-line),
LRM (line-reflective-match); pitch range: 40 to 150 μm |
|
RC-EM7-208230-60-CE |
Recirculating chiller; P2, 208 to 230 V, 60 Hz, 15 A, 5 kW, 15.1 L/min (4 gal/min), 60 psi |
|
RC-EM7-200-50-CE |
Recirculating chiller; P2, 200 V, 50 Hz, 15 A, 4.4 kW, 12.5 L/min (3.3 gal/min), 60 psi |
|
RC-EM7-400-50-CE |
Recirculating chiller; P2, 380-400 V, 50 Hz, 3-phase, 20 A, 6.425 kW, 12.5 L/min (3.3 gal/min), 60 psi |
| |
|
| |
| U.S.
And Canada Only Shipping |
| At this time, we cannot ship or bill web orders outside of the United States and Canada. We cannot accept credit cards issued from a bank outside of the U.S. or Canada. If you are outside of the U.S. or Canada and would like export prices or order information, please contact your local sales representative by visiting http://www.lakeshore.com/com/sr.html. |
|
| Sales
Tax: Lake Shore currently collects sales tax in the following
states: AZ, CA, FL, IN, OH, SC WA |
|
|
Terms & Conditions | Warranty Statement | Shipping Charges |
| Please submit your customized system for quotation by clicking on the button below. You will then be prompted to check your specifications, and once approved, these will be e-mailed to our sales department for a quote. |
| |
| |
|
|
|
 |
 |
 |