Contact: info@lakeshore.com Lakeshore.com Search www.lakeshore.com Contact Us Ordering / Pricing Products Home
 
View Cart
 
Home > Lake Shore Products > Cryogenic Probe Stations > Request A Quote for Model CRX-4K Cryogenic Probe Station
 

 Model CRX-4K

 Cryogen-Free 4 K Closed Cycle Refrigerator-Based Cryogenic Probe Station
 
Request Quote Model EMTTP4 Cryogenic Probe Station Product Overview Technical Specifications for Model EMTTP4 Cryogenic Probe Station Downloads for Model EMTTP4 Cryogenic Probe Station
 
Quantity Part Number Description 
CRX-4K Up to 6 micro-manipulated stage CCR-based cryogen free 2-inch wafer probe station
Configurable Options:
Probes, probe tips, and cables are user configurable options and are required
Up to Six XYZ Precision Micro-manipulated Stages
MMS-09 Micro-manipulated stage with thermal radiation shields, stainless steel welded bellows, and feedthrough ports—includes probe arm and base; probes, probe tips, and cables sold separately
     
ZN50-26U 50 W stripline probe body mount
 
ZN50 Probe tips (Alumina Ceramic Blade)
ZN50R-03-W 3 μm radius, tungsten, up to 1 GHz*
ZN50R-10-W 10 μm radius, tungsten, up to 1 GHz*
ZN50R-25-W 25 μm radius, tungsten, up to 1 GHz*
ZN50R-03-P7 3 μm radius, Paliney 7, up to 1 GHz*
ZN50R-10-P7 10 μm radius, Paliney 7, up to 1 GHz*
ZN50R-25-P7 25 μm radius, Paliney 7, up to 1 GHz*
ZN50R-03-BECU 3 μm radius, beryllium copper, up to 1 GHz*
ZN50R-10-BECU 10 μm radius, beryllium copper, up to 1 GHz*
ZN50R-25-BECU 25 μm radius, beryllium copper, up to 1 GHz*
ZN50R-100-BECU 100 μm radius, beryllium copper, up to 1 GHz*
ZN50R-200-BECU 200 μm radius, beryllium copper, up to 1 GHz*
* Maximum frequency is 50 MHz with ZN50C-G or ZN50C-T cable. Maximum frequency is 1GHz with MWC-09-00K cable.
ZN50 DC/RF Cables (Click here for more information on Z50 Cables)
ZN50C-G Ultra-miniature cryogenic coaxial probe cable with SMA plug at probe end, BNC feedthrough, and grounded shield (shielded measurements to 50 MHz, 475 K)
ZN50C-T Ultra-miniature cryogenic coaxial probe cable with SMA plug at probe end to 3-lug triaxial feedthrough (for low leakage guarded measurements to 50 MHz, 475 K)
MWC-09-00K Semirigid microwave coaxial probe cable with K (SMA compatible) plug at probe end and K (SMA compatible) socket at feedthrough end (for high frequency measurements to 1 GHz*, 400 K)
*S21 > -10 dB up to 1 GHz, except for a (-40 dB) spike between 400 MHz and 800 MHz depending on probe model and placement; S11< -3 dB up to 1 GHz
GSG Microwave Probes (Click here for more information on GSG Microwave Probes)
GSG-050-40A-26U-E K connector, 40 GHz, 50 μm pitch
GSG-100-40A-26U-E K connector, 40 GHz, 100 μm pitch
GSG-150-40A-26U-E K connector, 40 GHz, 150 μm pitch
GSG-200-40A-26U-E K connector, 40 GHz, 200 μm pitch
GSG-250-40A-26U-E K connector, 40 GHz, 250 μm pitch
   
GSG-050-50A-26U-E 2.4 mm connector, 50 GHz, 50 μm pitch
GSG-100-50A-26U-E 2.4 mm connector, 50 GHz, 100 μm pitch
GSG-150-50A-26U-E 2.4 mm connector, 50 GHz, 150 μm pitch
GSG-200-50A-26U-E 2.4 mm connector, 50 GHz, 200 μm pitch
GSG-250-50A-26U-E 2.4 mm connector, 50 GHz, 250 μm pitch
   
GSG-050-67A-26U-E 1.85 mm connector, 67 GHz, 50 μm pitch
GSG-100-67A-26U-E 1.85 mm connector, 67 GHz, 100 μm pitch
GSG-150-67A-26U-E 1.85 mm connector, 67 GHz, 150 μm pitch
GSG-200-67A-26U-E 1.85 mm connector, 67 GHz, 200 μm pitch
GSG-250-67A-26U-E 1.85 mm connector, 67 GHz, 250 μm pitch
GSG-TPM Theta planarization module with upgraded probe manipulator to accommodate microwave probe rotation mechanism for in situ probe planarization. (Included with each GSG probe ordered with a probe station. When purchasing a GSG probe alone, GSG-TPM is not included.)
GSG Microwave Cables (Click here for more information on GSG Microwave Cables)
MWC-09-00K Semirigid microwave coaxial probe cable with K (SMA compatible) plug at probe end and K (SMA compatible) socket at feedthrough end (for measurements to 40 GHz, 350 K)
MWC-09-240 Semirigid microwave coaxial probe cable with a 2.4 mm plug at probe and socket feedthrough ends (for measurements to 50 GHz, 350 K)
MWC-09-185 Semirigid microwave coaxial probe cable with a 1.85 mm plug at probe and socket feedthrough ends (for measurements to 67 GHz, 350 K)
Sample Chucks (Holders) – Each base system includes one SH-1.25-G (grounded) sample holder
(Click here for more information on Sample Chucks)
SH-1.25-G Grounded sample holder for up to 32 mm (1.25 in) diameter samples (350 K)
SH-1.25-I Isolated sample holder for up to 32 mm (1.25 in) diameter samples (350 K)
SH-1.25-C Coaxial sample holder for up to 32 mm (1.25 in) diameter samples (350 K)*
SH-1.25-T Triaxial sample holder for up to 32 mm (1.25 in) diameter samples (350 K)**
SH-2.00-G Grounded sample holder for up to 51 mm (2 in) diameter samples (350 K)
SH-2.00-C Coaxial sample holder for up to 51 mm (2 in) diameter samples (350 K)*
SH-2.00-C-HT High temperature coaxial sample holder for up to 51 mm (2 in) diameter samples (475 K)*—Requires PS-HTA, purchased separately
SH-2.00-T Triaxial sample holder for up to 51 mm (2 in) diameter samples (350 K)**
*Coaxial sample holders require one FT-BNC or FT-TRIAX feedthrough as listed below
**Triaxial sample holders require one FT-TRIAX feedthrough as listed below
FT-BNC Coaxial feedthrough and coaxial cable, installed and wired
FT-TRIAX Triaxial feedthrough and coaxial cable, installed and wired
Probe Station Options:
PS-FOA Fiber optic probe arm modification. Transmit or receive light or IR/UV radiation. Fiber optic terminated with SMA connector or compression feedthrough. (Fiber optic wire not included and priced separately based on requirements outlined in fiber optic worksheet. Fiber optic and probe cannot be used simultaneously.)
PS-HTA High temperature option kit used in combination with high temperature sample holders for temperature operation from 50 K (base), 55 K (control) to 475 K. Includes integrated thermal standoff, calibrated PT-100 temperature sensor, heater, wiring, and cabling. The high temperature sample assembly is interchangeable; standard sample holders can be used when the high temperature sample holder is removed
PS-Z16 16:1 zoom monoscope upgrade; provides 4 μm resolution NOTE: consult Lake Shore for field upgrade
PS-V81DP Turbo pumping system—includes Varian V-81 turbo pump cart with oil free dry scroll backing pump, vacuum gauging for high vacuum and fore line, controller, and adaptors (specify 120 V/60 Hz or 220 V/50 Hz)
PS-PLVI-40 Pump-line vibration isolator—includes NW40 fittings, 1 m stainless steel bellows, clamps, and rings (placed between pump cart and system); requires one bag of cement
PA-SEN Probe arm modification with temperature sensor installed and wired to a 6-pin feedthrough

PS-PAB-09 Probe arm and base
CS-5 Calibration substrate for GSG probes—pad size: 50 µm2; calibration type: SOLT (short-open-load-through), LRL (line-reflective-line), LRM (line-reflective-match); pitch range: 75 to 250 µm
CS-15 Calibration substrate for GSG probes—pad size: 25 µm2; calibration type: SOLT (short-open-load-through), LRL (line-reflective-line), LRM (line-reflective-match); pitch range: 40 to 150 µm
 
Special Request:
   
 
U.S. And Canada Only Shipping
At this time, we cannot ship or bill web orders outside of the United States and Canada. We cannot accept credit cards issued from a bank outside of the U.S. or Canada. If you are outside of the U.S. or Canada and would like export prices or order information, please contact your local sales representative by visiting http://www.lakeshore.com/com/sr.html.
Sales Tax: Lake Shore currently collects sales tax in the following states: AZ, CA, FL, IN, OH, SC WA
Terms & Conditions | Warranty Statement | Shipping Charges
Please submit your customized system for quotation by clicking on the button below. You will then be prompted to check your specifications, and once approved, these will be e-mailed to our sales department for a quote.
 
     
Spacer Spacer Spacer
 
 
 Home     |     Products     |     Ordering/Pricing     |     Search     |     Site Map
 
Privacy Policy | ©2007 Lake Shore Cryotronics, Inc.