Contact: info@lakeshore.com Lakeshore.com Search www.lakeshore.com Contact Us Ordering / Pricing Products Home
 
Add Model CPX Cryogenic Probe Station To Cart View Cart
 
Home > Lake Shore Products > Cryogenic Probe Stations > Model CPX Cryogenic Probe Station Tech Specs
 

 Model CPX

 Field-Upgradeable Cryogenic Probe Station
 
tech specs Model CPX Cryogenic Probe Station Product Overview Request A Quote for Model CPX Cryogenic Probe Station Downloads for Model CPX Cryogenic Probe Station
 
Specifications
 
Temperature
Operating temperature range—overall  1.5 K to 475 K*
    ZN50 DC/RF probe with low RF cryogenic coaxial cable  1.5 K to 475 K*
     ZN50 DC/RF probe with high RF semirigid coaxial cable
 1.5 K to 475 K*
     GSG microwave probe with semirigid coaxial cable
 1.5 K to 475 K*
Temperature control (heater)

     Sample stage
 50 W
     Radiation shields  Two 100 W and one 50 W
     Probe arm  Measurement only
* Selectable equipment
 
Probe Arm and Sample Stage Adjustments
Travel
     X axis  51 mm (2 in)
     Y axis
 25 mm (1 in)
     Z axis
 18 mm (0.7 in)
Translation scale
     X axis  20 µm
     Y and Z axes
 10 µm
    Theta planarization*
 ±5°
Sample stage (sample holder)
     In-plane rotation  ±5°
*Included with microwave probes
 
Frequency Range
ZN50 DC/RF probe frequency range

     Tungsten with cryogenic coaxial cable
 0 to 50 MHz*
     Tungsten with semirigid coaxial cable  0 to 1 GHz*†
     Paliney 7 with cryogenic coaxial cable  0 to 50 MHz*
     Paliney 7 with semirigid coaxial cable  0 to 1 GHz*†
     BeCu with cryogenic coaxial cable  0 to 50 MHz*
     BeCu with semirigid coaxial cable  0 to 1 GHz*†
GSG microwave probe frequency range

     Low frequency with K connector
 0 to 40 GHz*
     Mid frequency with 2.4 mm connector  0 to 50 GHz*
     High frequency with 1.85 mm connector  0 to 67 GHz*
arrow Click here for probe & cable features
* Selectable equipment
† S21 > -10 dB up to 1 GHz, except for a (-40 dB) spike between 400 MHz and 800 MHz depending on probe model and placement; S11 < -3 dB up to 1
GHz
 
Optical
Optical viewport—located on top lids  Ø54 mm (2.13 in) outer window and Ø50 mm (2 in) inner window
     Outer, clear fused quartz  99% IR transmittance
     Inner  IR absorbing with narrow band visible light transmittance
Optical resolution—microscope  
     7:1 zoom  4 μm
     16:1 zoom  4 μm*
* Selectable equipment
 
Sample Holder (Chuck)
Maximum sample size—overall  Up to Ø51 mm (2 in)*
     SH-1.25-G, grounded chuck  Up to Ø32 mm (1.25 in) and 475 K
     SH-1.25-I, isolated chuck  Up to Ø32 mm (1.25 in) and 400 K*
     SH-1.25-C, coaxial chuck  Up to Ø32 mm (1.25 in) and 400 K*
     SH-1.25-T, triaxial chuck  Up to Ø32 mm (1.25 in) and 400 K*
     SH-2.00-G, grounded chuck  Up to Ø51 mm (2 in) and 475 K*
     SH-2.00-C, coaxial chuck  Up to Ø51 mm (2 in) and 400 K*
     SH-2.00-T, triaxial chuck  Up to Ø51 mm (2 in) and 400 K*
*Selectable equipment
garrow Click here to select a sample chuck (holder)
 
Standard Equipment
Flow cryostat
 4.2 K to 475 K
     Sample stage temperature sensor  Lake Shore Model DT-670-SD-1.4H calibrated silicon diode
     Sample stage heater  50 W
Cooled radiation shield and cooled IR-absorbing window above the sample
     Radiation shield temperature sensors  Three Lake Shore Model DT-670C-CU silicon diodes
     Radiation shield heaters  Two 100 W and one 50 W
     Removable top lid with viewport  Ø50 mm (2 in) window
Temperature controllers

One Lake Shore Model 340 temperature controller with 3462 expansion card, one Lake Shore Model 332S temperature controller, and one Lake Shore Model 142 200 W (2 channels, 100 W each) power supply (independent regulation of sample stage and radiation shields, and probe arm temperature monitoring)

Electroless nickel-plated aluminum vacuum chamber
     Diameter  279 mm (11 in)
     Removable top lid with clear fused quartz viewport  Ø54 mm (2.13 in) window
     Probe ports  6 surround the sample thermal radiation shield
     Pump port  NW40 (pump sold separately)
     Gas purge and 0.5 psi safety pop-off port  NW25
     Option port  High vacuum
     Spare ports  NW40 and NW25
Machined aluminum base plate
 610 mm × 737 mm (24 in × 29 in)
Support stand
 Heavy duty welded steel stand—optional pneumatic vibration isolation
 system available
Temperature sensor installed and wired to a 6-pin feedthrough (included on one probe arm)
Grounded sample holder
 SH-1.25-G, accommodates up to a Ø32 mm (1.25 in) sample with a
 Ø25 mm (1 in) probe area
Optics
     
     Zoom 70 microscope
 7:1 zoom with 4 μm resolution
     Color CCD camera  S-video or composite output format
     Swing arm  Optics can be manipulated to view any part of the sample or wafer, and can  be retracted and swung away to allow access to the top of the vacuum  chamber for sample exchange
     Video monitor  High resolution, 17-inch
     Sample illumination  Coaxial via fiber optic or ring light from an adjustable light source and power
 supply (must specify sample illumination at time of order) NOTE: Coaxial  illumination is recommended for highly reflective  materials
High efficiency helium transfer line with foot valve for precise flow regulation
Instrument console
Basic tools and spares kit for standard operation
 
Spacer Spacer
 