| Quantity |
Part Number |
Description |
|
CPX |
Up to 6 micro-manipulated stage 2-inch wafer configurable probe station |
| Configurable Options: |
| Probes, probe tips, and cables are user configurable options and are required |
| Up to Six XYZ Precision Micro-manipulated Stages |
|
MMS-09 |
Micro-manipulated stage with thermal radiation shields, stainless steel welded bellows, and feedthrough ports—includes probe
arm and base; probes, probe tips, and cables sold separately |
| ZN50 DC/RF Probes |
|
ZN50-55I |
50 W stripline probe body mount |
| ZN50 Probe Tips (Alumina Ceramic Blade) |
|
ZN50R-03-W |
3 μm radius, tungsten, up to 1 GHz* |
|
ZN50R-10-W |
10 μm radius, tungsten, up to 1 GHz* |
|
ZN50R-25-W |
25 μm radius, tungsten, up to 1 GHz* |
|
ZN50R-03-P7 |
3 μm radius, Paliney 7, up to 1 GHz* |
|
ZN50R-10-P7 |
10 μm radius, Paliney 7, up to 1 GHz* |
|
ZN50R-25-P7 |
25 μm radius, Paliney 7, up to 1 GHz* |
|
ZN50R-03-BECU |
3 μm radius, beryllium copper, up to 1 GHz* |
|
ZN50R-10-BECU |
10 μm radius, beryllium copper, up to 1 GHz* |
|
ZN50R-25-BECU |
25 μm radius, beryllium copper, up to 1 GHz* |
|
ZN50R-100-BECU |
100 μm radius, beryllium copper, up to 1 GHz* |
|
ZN50R-200-BECU |
200 μm radius, beryllium copper, up to 1 GHz* |
| * Maximum frequency is 50 MHz with ZN50C-G or ZN50C-T cable. Maximum frequency is 1 GHz with MWC-10-00K-NM cable. |
| ZN50 DC/RF Cables (Click here for more information on Z50 Cables) |
|
ZN50C-G |
Ultra-miniature cryogenic coaxial probe cable with SMA plug at probe end, BNC feedthrough, and grounded shield (shielded
measurements to 50 MHz, 475 K) |
|
ZN50C-T |
Ultra-miniature cryogenic coaxial probe cable with SMA connector at probe end to 2-lug triax feedthrough (for low leakage
guarded measurements to 50 MHz, 475 K); 2-lug to 3-lug adapter included |
|
MWC-09-00K |
Semirigid microwave coaxial probe cable with K (SMA compatible) plug at probe end and K (SMA compatible) socket at
feedthrough end (for high frequency measurements to 1 GHz*, 475 K) |
| *S21 > -10 dB up to 1 GHz, except for a (-40 dB) spike between 400 MHz and 800 MHz depending on probe model and placement;
S11 < -3 dB up to 1 GHz |
| GSG Microwave Probes (Click here for more information on GSG Microwave Probes) |
|
GSG-050-40A-55I-E |
K connector, 40 GHz, 50 μm pitch |
|
GSG-100-40A-55I-E |
K connector, 40 GHz, 100 μm pitch |
|
GSG-150-40A-55I-E |
K connector, 40 GHz, 150 μm pitch |
|
GSG-200-40A-55I-E |
K connector, 40 GHz, 200 μm pitch |
|
GSG-250-40A-55I-E |
K connector, 40 GHz, 250 μm pitch |
| |
|
GSG-050-50A-55I-E |
2.4 mm connector, 50 GHz, 50 μm pitch |
|
GSG-100-50A-55I-E |
2.4 mm connector, 50 GHz, 100 μm pitch |
|
GSG-150-50A-55I-E |
2.4 mm connector, 50 GHz, 150 μm pitch |
|
GSG-200-50A-55I-E |
2.4 mm connector, 50 GHz, 200 μm pitch |
|
GSG-250-50A-55I-E |
2.4 mm connector, 50 GHz, 250 μm pitch |
| |
|
GSG-050-67A-55I-E |
1.85 mm connector, 67 GHz, 50 μm pitch |
|
GSG-100-67A-55I-E |
1.85 mm connector, 67 GHz, 100 μm pitch |
|
GSG-150-67A-55I-E |
1.85 mm connector, 67 GHz, 150 μm pitch |
|
GSG-200-67A-55I-E |
1.85 mm connector, 67 GHz, 200 μm pitch |
|
GSG-250-67A-55I-E |
1.85 mm connector, 67 GHz, 250 μm pitch |
|
GSG-TPM |
Theta planarization module with upgraded manipulator to accommodate microwave probe rotation mechanism for in situ probe planarization (included with each GSG probe ordered with a probe station. When purchasing a GSG probe alone, GSG-TPM is not included) |
| GSG Microwave Cables (Click here for more information on GSG Microwave Cables) |
|
MWC-09-00K |
Semirigid microwave coaxial probe cable with K (SMA compatible) plug at probe end and K (SMA compatible) socket at
feedthrough end (for measurements to 40 GHz, 475 K) |
|
MWC-09-185 |
Semirigid microwave coaxial probe cable with a 1.85 mm plug at probe and socket feedthrough ends (for measurements to
67 GHz, 475 K) |
|
MWC-09-240 |
Semirigid microwave coaxial probe cable with a 2.4 mm plug at probe and socket feedthrough ends (for measurements to
50 GHz, 475 K) |
| Sample holders – Each base system includes one SH-1.25-G (grounded) sample holder (Click here for more information on Sample Chucks) |
|
SH-1.00-G |
Grounded sample holder for up to 25 mm (1 in) diameter samples (400 K) |
|
SH-1.00-I |
Isolated sample holder for up to 25 mm (1 in) diameter samples (400 K) |
|
SH-1.00-C |
Coaxial sample holder for up to 25 mm (1 in) diameter samples (400 K)* |
|
SH-1.00-T |
Triaxial sample holder for up to 25 mm (1 in) diameter samples (400 K)** |
|
SH-1.25-G |
Grounded sample holder for up to 32 mm (1.25 in) diameter samples (475 K) |
|
SH-1.25-I |
Isolated sample holder for up to 32 mm (1.25 in) diameter samples (400 K) |
|
SH-1.25-C |
Coaxial sample holder for up to 32 mm (1.25 in) diameter samples (400 K)* |
|
SH-1.25-T |
Triaxial sample holder for up to 32 mm (1.25 in) diameter samples (400 K)** |
|
SH-2.00-G |
Grounded sample holder for up to 51 mm (2 in) diameter samples (475 K) |
|
SH-2.00-C |
Coaxial sample holder for up to 51 mm (2 in) diameter samples (400 K)* |
|
SH-2.00-T |
Triaxial sample holder for up to 51 mm (2 in) diameter samples (400 K)** |
*Coaxial sample holders require one FT-BNC or FT-TRIAX feedthrough as listed below
**Triaxial sample holders require one FT-TRIAX feedthrough as listed below |
|
FT-BNC |
Coaxial feedthrough and coaxial cable, installed and wired |
|
FT-TRIAX |
Triaxial feedthrough and coaxial cable, installed and wired |
| Probe Station Options: |
|
PS-HV-CPX |
High vacuum option. Ensures that condensation does not accumulate in the sample environment during cooldown. This
is critical for measuring organic semiconductors and for high Z and low current applications. Includes HVAC port, Varian V301
turbo pump kit, and related HVAC components. Vacuum specifications: radiation shields at room temperature with DUT at maximum
temperature: 10-5 torr; room temperature: 10-6 torr; cold radiation shields with DUT at maximum temperature: 10-6 torr; cold radiation shields
with DUT at room temperature or below: 10-7 torr |
|
PS-LL-CPX |
Load-lock assembly option. Allows sample exchange without warming the radiation shields or breaking vacuum,
significantly improving efficiency and throughput by reducing cycle time to roughly 1 h. Load-lock also allows samples to be
exchanged under controlled environmental conditions. Overall temperature range limited from 10 K to 400 K when using this option. |
|
PS-SSVAC-CPX |
Stainless steel vacuum chamber and lid upgrade; supplied in place of standard aluminum vacuum chamber |
|
PS-FOA |
Fiber optic probe arm modification. Transmit or receive light or IR/UV radiation. Fiber optic terminated with SMA connector or
compression feedthrough. (Fiber optic wire not included and priced separately based on requirements outlined in fiber optic worksheet.
Fiber optic and probe cannot be used simultaneously.) |
|
PS-Z16 |
16:1 zoom microscope upgrade; provides 5 μm resolution NOTE: consult Lake Shore for field upgrade |
|
PS-LT |
2.0 K base temperature stage pumping option—includes system modifications, stainless steel flex hose for pump connection, and
Varian DS402 rotary pump (12.3 CFM at 60 Hz with oil mist eliminator on output [with oil return], and inlet oil demister); 50 Hz operation may
increase base temperature |
|
PS-VLT-CPX |
1.5 K base temperature assembly—includes adapter, 4 K shield, and Model SH-1.00-G 25mm (1 inch) grounded sample holder
NOTE: must be purchased in addition to PS-LT; maximum sample size limited to 25 mm (1 in) with this option—additional sample
holders sold separately; 50 Hz operation may increase base temperature |
|
PS-PLVI-25 |
Pump-line vibration isolator—includes NW25 fittings, 1 m stainless steel bellows, clamps, and rings (placed between pump cart
and system); requires one bag of cement |
|
PS-V81DP |
Turbo pumping system—includes Varian V-81 turbo pump cart with oil free dry scroll backing pump, vacuum gauging for high
vacuum and fore line, controller, and adaptors (specify 120 V/60 Hz or 220 V/50 Hz) |
|
PS-PLVI-40 |
Pump-line vibration isolator—includes NW40 fittings, 1 m stainless steel bellows, clamps, and rings (placed between pump cart
and system); requires one bag of cement |
|
PS-DPC |
Automatic Dewar (gas) pressure controller, regulates Dewar liquid flow |
|
PS-LN2 |
Nitrogen Dewar with stainless fittings, gauges, and adaptors; allows LN2 use with the LHe transfer line |
|
PS-PVIS |
Pneumatic vibration isolation system—gimbal piston isolator, actuators, and supports (isolator natural frequency: vertical 0.8 Hz,
horizontal 1.0 Hz; isolation efficiency at 5 Hz: vertical 80 to 97%, horizontal 60 to 90%; efficiency at 10 Hz: vertical 90 to 99%, horizontal 70 to
95%); requires 40 psi nitrogen or air |
|
PS-OAC |
Oil-less air compressor for PS-TMC (only available in 120 V) |
|
PA-SEN |
Probe arm modification with temperature sensor installed and wired to a 6-pin feedthrough |
|
PS-PAB-09 |
Probe arm and base |
|
CS-5 |
Calibration substrate for GSG probes—pad size: 50 μm2; calibration type: SOLT (short-open-load-through), LRL (line-reflective-line),
LRM (line-reflective-match); pitch range: 75 to 250 μm |
|
CS-15 |
Calibration substrate for GSG probes—pad size: 25 μm2; calibration type: SOLT (short-open-load-through), LRL (line-reflective-line),
LRM (line-reflective-match); pitch range: 40 to 150 μm |
| |
|
| |
| U.S.
And Canada Only Shipping |
| At this time, we cannot ship or bill web orders outside of the United States and Canada. We cannot accept credit cards issued from a bank outside of the U.S. or Canada. If you are outside of the U.S. or Canada and would like export prices or order information, please contact your local sales representative by visiting http://www.lakeshore.com/com/sr.html. |
|
| Sales
Tax: Lake Shore currently collects sales tax in the following
states: AZ, CA, FL, IN, OH, SC WA |
|
|
Terms & Conditions | Warranty Statement | Shipping Charges |
| Please submit your customized system for quotation by clicking on the button below. You will then be prompted to check your specifications, and once approved, these will be e-mailed to our sales department for a quote. |
| |
| |
|
|
|
 |
 |
 |