 Model 642 Electromagnet Power Supply
 
Technical Specifications Downloads Ordering Information Product Overview
 
Specifications
 
Output  
Type Bipolar, 4-quadrant, DC current source
Current generation Fully linear regulation with digital setting and analog control
Current range ±70 A
Compliance
voltage (DC)
±35 V nominal
Power 2450 W nominal
Load resistance range 0.4 W to 0.6 W
Load inductance range

0 to 1 H

Nominal load 0.5 W, 0.5 H
Current ripple 5 mA RMS (0.007%) at 70 A into nominal load
Current ripple frequency Dominated by the line frequency and its harmonics
Temperature coefficient ±15 ppm of full scale/°C
Line regulation ±60 ppm of full scale/10% line change
Stability (1 h)

1 mA/h (after warm-up)

Stability (24 h) 5 mA/24 h (typical, dominated by temp. coefficient and line regulation)
Isolation Differential output is optically isolated from chassis to prevent ground loops
Slew rate 50 A/s into nominal load , 650 A/s minimum into a resistive load
Compliance voltage (AC) ±43 V nominal
Setting time <1 s for 10% step to within 1 mA of output into nominal load
Modulation response 0.17 Hz at ±70 A sine wave into nominal load, <0.02% THD; 10 Hz at ±10 A sine wave into nominal load, <0.10% THD
Attenuation -0.5 dB at 10 Hz
Protection Short circuit, line loss, low line voltage, high line voltage, output over voltage, output over current, and over temperature
Connector Two lugs with 6.4 mm (0.25 in) holes for M6 or 0.25 in bolts
Spacer Spacer
   
Output Programming
Internal current setting
    Resolution 0.1 mA (20-bit)
    Settling time 600 ms for 1% step to within 1 mA (of internal setting)
    Accuracy ±10 mA ±0.05% of setting
    Operation Keypad, computer interface
    Protection Programmable current setting limit
Internal current ramp
    Ramp rate 0.1 mA/s to 99.999 A/s (complaince limited)
    Update rate

23.7 increments/s

    Ramp segments 5
    Operation Keypad, computer interface
    Protection Programmable ramp rate limit
External current programming
    Sensitivity 10 V/70 A
    Resolution Analog
    Accuracy

±10 mA ±1% of setting

    Input resistance 20 kW
    Operation Voltage program through rear panel, can be summed with internal current setting
    Limits Internally clamped at ±10.1 V and bandwidth limited at 40 Hz to protect output
    Connector Shared 15-pin D-sub
Spacer Spacer
   
Readings
Output current
    Resolution 0.1 mA
    Accuracy ±5 mA ±0.05% of reading
    Update rate 2.5 rdg/s display, 10 rdgs/s interface
Output voltage (at supply terminals)
    Resolution 1 mV
    Accuracy

±5 mV ±0.05% of rdg

    Update rate 2.5 rdg/s display, 5 rdg/s interface
Spacer Spacer
 
Front Panel
Display type 8-line by 40-character, graphic vacuum fluorescent module
Display readings Output current, output voltage, and internal water temperature
Display settings Output current and ramp rate
Display annuciators Status and errors
LED annuciators Fault, Compliance, Power Limit, Ramping, Remote
Audible annuciator Errors and faults
Keypad type 26 full-travel keys
Keypad functions

Direct access to common operations, menu driven setup

Power White flush ON and black extended OFF push buttons
Spacer Spacer
Interface
IEEE-488.2 interface
    Features SH1, AH1, T5, L4, SR1, RL1, PP0, DC1, DT0, C0, E1
    Reading rate To 10 rdg/s
    Software support National Instruments LabVIEW™ driver
(consult Lake Shore for availability)
Serial interface
    Electrical format RS-232C
    Baud rates

9600, 19200, 38400, 57600

    Reading rate To 10 rdg/s
    Connector 9-pin D-sub (DTE)
Output current monitor
    Sensitivity 7 V = 10 A
    Accuracy ±1% of full scale
    Noise

1 mV RMS

    Source impedence 20 W
    Connector Shared 15-pin D-sub
Output voltage monitor
    Sensitivity 3.5 V = 35 V
    Accuracy 1% of full scale
    Noise 1 mV RMS
    Source impedence 20 W
    Connector Shared 15-pin D-sub
Power supply cooling water
    Remote enable input TTL low or contact closure to enable output; jumper required if unused
    Valve power output 24 VAC at 1 A maximum, automatic or manual control
    Connector

Shared 4-pin detachable terminal block

Flow switch and water valve optional
Magnet cooling water
    Remote enable input TTL low or contact closure to enable output; jumper required if unused
    Valve power output 24 VAC at 1 A maximum, automatic or manual control
    Connector

Shared 4-pin detachable terminal block

Flow switch and water valve optional
Auxiliary
    Emergency stop Requires 1 A, 24 VAC normally closed contact closure to enable power-up; jumper required if unused
    Fault output

Relay with normally open or normally closed contact, 30 VDC at 1 A

    Remote enable input TTL low or contact closure to enable output; jumper required if unused
    Connector

Shared 8-pin detachable terminal block

Emergency stop and inhibit switches not included
Spacer Spacer
   
General
Input power
    Power 5500 VA max
    Voltage & current 204/208 VAC ±10%, 13 A/phase; 220/230 VAC ±10%, 12 A/phase; 380 VAC ±10%, 7 A/phase; 400/415 VAC ±10%, 6.5 A/phase
    Protection 3-phase thermal relay with adjustable current setting. Two class CC ¼ A fuses. Over-voltage lockout circuit.
    Frequency 50 or 60 Hz
    Configuration 3-phase delta
    Connector 4-pin terminal block
Line voltage must be specified at time of order but is field reconfigurable; cable from power supply to facility power not included
Cooling water
    Flow rate 5.7 L (1.5 gal) per min minimum
    Pressure range

34 kPa (5 PSI) to 552 kPa (80 PSI)

    Pressure drop 10 kPa (1.5 PSI) at 5.7 L (1.5 gal) per min minimum for power supply only
    Temperature 15 °C to 30 °C (non condensing)
    Connection Two 10 mm (0.375 in) hose barbs
CAUTION: Internal condensation can cause damage to the power supply
 
Enclosure type 7 U High, 19 in rack mount with integral rack mount ears, 25 mm (1 in) air space required on each side for ventilation
Size 48.3 cm W × 31.0 cm H × 57.2 cm D (19 in × 12.2 in × 22.5 in) with handles removed
Weight 74 kg (163 lb)
Shipping size 63.5 cm W × 55.9 cm H × 73.7 cm D (25 in × 22 in × 29 in)
Shipping weight 80 kg (175 lb)
Ambient temperature 15 °C to 35 °C at rated accuracy, 5 °C to 40 °C at reduced accuracy
Humidity 80% to 31 °C decreasing linearly to 50% at 40 °C, (non condensing)
Warm-up 30 min at output current setting
Approvals CE mark–low voltage compliance to EN61010-3, EMC compliance to EN55022-1
Calibration schedule 1 year